The STR-3222-R1 is a smart lighting control module designed specifically for staircase LED strip effects. It enables dynamic step-by-step lighting triggered by motion sensors or wall switches, and integrates seamlessly into MiniPLC and MicroPLC platforms via RS‑485 Modbus RTU. Powered by the RP2350 microcontroller, the module delivers responsive control, smooth dimming sequences, and flexible automation logic.

Back on Kickstarter

Be among the first to receive the HomeMaster products by backing our Kickstarter campaign.

  • Early-bird rewards available while supplies last
  • You’re only charged if the campaign reaches its goal
  • Support reliable, local, open-source automation

140.00 140.0 USD 140.00 Tax Excluded

0.00 lei Tax Excluded

PRE-ORDER

    This combination does not exist.


    Display Name: STR-3221-R1

    STR-3221-R1 — Module for Smart Lighting & I/O Control

    HOMEMASTER – Modular control. Custom logic.

    Image

    1. Introduction

    1.1 Overview of the STR-3221-R1

    The STR-3221-R1 is a compact and configurable smart LED / I/O controller designed for multi-channel LED lighting and automation control in architectural and industrial applications.

    It provides 32 MOSFET-switched outputs (open-drain, low-side, 12–24 V DC) for LED loads, along with 4 opto-isolated 24 V digital inputs and 4 local buttons each with indicator LEDs.
    Configuration is handled through a browser-based WebConfig interface via USB-C (Web Serial) — no additional software or drivers are required.

    The module communicates with a MicroPLC/MiniPLC or any Modbus master via RS-485 (Modbus RTU), making it ideal for staircase lighting, building automation, ambient illumination, alarm signaling, or other automation systems.

    Internally, it features robust isolation, surge protection, and power regulation circuits, ensuring reliable field operation and long service life.

    One-line purpose: a high-density field I/O lighting node that’s easy to wire, configure, and supervise from PLC, SCADA, or home automation platforms.


    1.2 Features & Architecture
    Subsystem Qty Description
    Digital Inputs 3 Opto-isolated 3V3 DC on terminals: IN1 (GND,+), IN2 (GND,+) for motion sensors, One DI for switch
    MOSFET Outputs 32 Low-side SI2307A per channel (O1…O32), 12–24 V loads; flyback SS24 diodes; grouped with shared VCC pins.
    LED Driver ICs 4 TLC59208F (8-ch constant-current sinks) used for status/indication and channel grouping/PWM.
    Buttons 4 SW1–SW4 for test/override or user logic.
    Status LEDs 4 User-assignable (steady/blink) for power/activity/logic states.
    Modbus RTU Yes RS-485 via MAX485 transceiver; activity LEDs.
    USB-C Yes WebConfig over Web Serial (Chromium-based browsers); ESD-protected port.
    Power 24 VDC Reverse/surge-protected input; AP64501 buck → 5 V, AMS1117-3.3 LDO → 3.3 V logic.
    MCU RP2350 + W25Q32 Dual-core MCU with external QSPI flash for firmware/config.
    Protection TVS, PTC Surge/ESD and resettable fuses across field & comms lines.

    Note: Two additional opto input circuits exist on the PCB design, but only IN1/IN2 are brought to terminals on this enclosure revision.


    1.3 System Role & Communication
    • Connection to RS-485 bus: wire controller A/B/COM to the module’s A/B/COM terminals (daisy-chain friendly, terminate the ends).
    • Operating mode: Modbus RTU slave; can run simple local patterns/tests from buttons, while a PLC/SCADA/HA supervises over Modbus.
    • Polling: Controller reads IN1/IN2 state and writes/reads O1…O32; optional mirrors for LEDs/buttons.
    • Defaults (changeable in WebConfig):
      • Address: 21
      • Baud: 115200 (8N1)

    2. STR-3221-R1 — Technical Specification

    2.1 Diagrams & Pinouts
    Diagrams & Descriptions
    System Diagram
    System Block Diagram — MCU, Modbus interface, power chain, and I/O groups.
    FieldBoard LayoutFieldBoard Layout — 32 MOSFET outputs, ISO1212 inputs, 24 VDC power rails.
    MCUBoard LayoutMCU Board Layout — RP2350 MCU, TLC59208F drivers, MAX485, and USB-C.
    Terminal MapPinOut — Field wiring view with power, DI, outputs, and RS-485.

    2.2 I/O Summary
    Interface Qty Description
    Digital Inputs 2 Opto-isolated 24 VDC via ISO1212 (U23), surge-protected (F6/F7, D39).
    Outputs 32 Low-side MOSFET (SI2307A) channels with SS24 flyback diodes, grouped with shared VCC rails.
    Buttons 4 Local control / override / test switches.
    Status LEDs 4 User-assignable (power, activity, or logic indicator).
    RS-485 (Modbus RTU) 1 Communication bus; A/B/COM terminals.
    USB-C (Setup Port) 1 WebConfig / firmware interface (not for powering field devices).
    Power Input 1 24 VDC (V+, 0V); reverse and surge-protected; onboard 5 V / 3.3 V regulation.
    Sensor Rails (SENS.A / SENS.B) 2 pairs Fused 24 V auxiliary rails for external sensors (low current).

    2.3 Electrical Specifications
    Parameter Min Typ Max Unit Notes
    Supply Voltage (V+) 20 24 30 VDC SELV input; reverse/surge protected.
    Logic Rails 5 / 3.3 VDC Generated internally (buck + LDO).
    Quiescent Current (no load) 60 100 mA Base electronics only.
    Full-Load Current (all outputs) 3.0 A At 24 VDC with max LED load.
    Digital Input Range 9 24 30 VDC ISO1212-rated 24 V input.
    Input Threshold (ON) 8 VDC Typical ISO1212 threshold.
    Sensor Rail Output 24 VDC Fused 200 mA (total SENS.A + SENS.B).
    Output Type Low-side MOSFET (SI2307A) 1 A max per channel.
    Flyback Protection SS24 diodes on each channel.
    Communication RS-485 (MAX485), 9600–115200 bps.
    Isolation Optical (ISO1212 + galvanic separation).
    Operating Temperature 0 40 °C 95 % RH non-condensing.

    ⚙️ Design domains:

    • Field side: 24 VDC isolated (DI, outputs).
    • Logic side: 5 V / 3.3 V MCU, I²C bus, USB-C protected.
    • Communication side: RS-485 isolated by line TVS + fuses.

    2.4 Firmware Behavior
    Function Description
    Input Processing Debounced and optically isolated; logic reported via Modbus coils/registers.
    Output Control 32 channels controlled via Modbus write commands; supports PWM dimming and timed activation sequences.
    Button Actions Assignable in firmware: manual test, override ON/OFF, or reset function.
    LED Feedback Configurable for steady, blink, or activity indication via TLC59208F drivers.
    Override Priority Local overrides (buttons) take precedence over Modbus commands until released.
    WebConfig (USB-C) Provides Modbus address setup, baud-rate selection, live I/O status, and firmware update through Web Serial.
    Startup Logic On power-up, outputs default to OFF until first Modbus command or internal script execution.
    Fault Handling Overcurrent or thermal events trigger fault LED indication; recover automatically when condition clears.

    🧩 Note:
    The STR-3221-R1 shares the same firmware architecture as other HOMEMASTER I/O modules, enabling unified Modbus mapping, button/LED behavior, and WebConfig interface.


    3. Use Cases

    These example illustrate how the STR-3221-R1 can be integrated into real-world automation or lighting systems.


    Motion-Based Stair Lighting

    What it does:
    Automatically lights stair LEDs in sequence when motion is detected at the top or bottom of the staircase.

    Setup:

    1. Connect motion sensors to IN1 (bottom) and IN2 (top) terminals.
    2. Connect each stair LED segment to outputs O1–O32 (low-side switching).
    3. Set WebConfig → STR-3221-R1 .
    4. Program MicoPLC/MiniPLC to poll IN1/IN2 and activate LEDs in a timed sequence.
    5. Use Button 1 as “Manual Test / All ON” and Button 2 as “All OFF”.

    4. Safety Information

    The STR-3221-R1 is a SELV (Safety Extra-Low Voltage) device.
    Improper wiring, power application, or grounding may cause malfunction or damage.
    Follow all safety and wiring practices described below.


    4.1 General Requirements
    Requirement Detail
    Qualified Personnel Only trained technicians familiar with control panels, PLCs, and SELV wiring should install or service this module.
    Power Isolation Always disconnect 24 VDC power and RS-485 trunk before touching or rewiring terminals.
    Rated Voltages Only Use SELV 24 VDC power supplies; never connect AC mains or high-voltage lines.
    Grounding Properly bond the panel’s protective earth (PE) to reduce EMI and static discharge.
    Enclosure Mount in a clean, dry, ventilated enclosure; avoid moisture, conductive dust, or vibration.
    Static Protection Handle circuit boards only with ESD precautions (grounded strap and antistatic mat).

    4.2 Installation Practices
    • DIN Mounting:
      Mount securely on 35 mm DIN rail (EN 50022) using the rear clip. Apply strain relief on all connected cables to prevent terminal stress.

    • Isolation Domains:
      The module contains isolated sections:

      • Field Power (24 VDC_FUSED) for outputs and inputs
      • Logic Power (5 V / 3.3 V) for MCU
        Never short or bridge GND_FUSED (field ground) with logic ground unless specifically required by system design.
    • Sensor Power Connection:
      Connect sensors or switches only to DI terminals rated for 24 VDC inputs.
      Sensor rails labeled SENS.A / SENS.B provide limited, fused 24 V service for low-power sensors — do not backfeed or parallel with other supplies.

    • Wiring Discipline:
      Use ferruled, properly sized conductors (0.25–1.5 mm²).
      Route communication (RS-485) and power lines separately to reduce noise coupling.

    • Testing Before Power-Up:
      Verify all terminal polarities, check RS-485 A/B orientation, and confirm no shorts between supply rails.


    4.3 Interface Warnings
    ⚡ Power (24 VDC Input / LED Supply)
    Area Warning
    24 VDC Power (V+ / 0V) Use only clean, regulated SELV 24 VDC. Reverse polarity is protected but repeated mistakes may damage fuses.
    LED PS (+/–) Provides the external LED load voltage (typically 12–24 VDC). Do not short or exceed rated current capacity of field wiring.
    Sensor Rails (SENS.A / SENS.B) For powering external sensors only; limited current via fuses. Never use to drive loads or feed back external power sources.

    🔌 Digital Inputs (DI)
    Area Warning
    Input Type Accepts 24 VDC logic signals (PNP, dry contact). No AC or high-voltage inputs.
    Isolation Each input isolated through ISO1212; do not bridge input commons to other supplies.
    Debounce Hardware filtering provided; avoid additional large RC filters that delay detection.
    Protection Each input fused and surge-protected (F6/F7, D39). Replace fuses only with identical PTC parts.

    ⚙️ Outputs (O1…O32)
    Area Warning
    Output Type Low-side MOSFET (SI2307A) sinks; maximum load per channel 1 A (12–24 VDC).
    Polarity Connect load +V to VCC group rail, load – to output terminal (O#).
    Flyback / Inductive Loads Built-in SS24 diodes; for large inductive loads add external RC or TVS snubbers.
    Shared Rail Each 8-channel group shares a VCC rail — ensure consistent LED supply voltage.

    🔄 RS-485 (Modbus RTU)
    Area Warning
    Wiring Use twisted pair (shielded) cable for A/B lines. Maintain consistent polarity along the trunk.
    Termination Terminate with 120 Ω resistors at both physical ends only.
    Ground Reference Connect COM to controller’s reference if using separate power supplies.
    Topology Daisy-chain preferred. Avoid star connections to prevent reflections.
    Surge Protection Integrated TVS diodes and fuses protect the transceiver; still use proper cable shielding in industrial environments.

    🧠 USB-C (Service / WebConfig)
    Area Warning
    Purpose For setup, diagnostics, and firmware only. Not for powering sensors or external devices.
    Connection Connect to PC via isolated USB hub if the RS-485 bus is long or exposed.
    During Operation Disconnect USB-C when running in the field; avoid ground loops with PLC systems.
    ESD Port is ESD-protected, but avoid static discharge when plugging in cables.

    ⚠️ Summary:
    The STR-3221-R1 is designed for SELV 24 VDC systems. Never connect mains voltages.
    Always de-energize and confirm wiring before service. Proper isolation, grounding, and shielding ensure safe and reliable operation.

    5. Installation & Quick Start

    5.1 What You Need
    Item Description
    Module MODULE-CODE unit
    Controller MiniPLC/MicroPLC or Modbus RTU master
    PSU Regulated 24 VDC
    Cable USB-C and RS-485 twisted pair
    Software Browser with Web Serial support
    5.2 Power
    • Describe 24 VDC input
    • List expected current
    • Explain isolated sensor power if present
    5.3 Communication
    • RS-485 pinout
    • Address & baudrate setup
    • Use of COM/GND reference
    5.4 Installation & Wiring

    Use diagrams and explain:

    • Inputs
    • Relays
    • Sensor rails (12/5V)
    • RS-485 terminals
    • USB port
    5.5 Software & UI Configuration

    Cover:

    • WebConfig setup (address, baud)
    • Input enable/invert/group
    • Relay logic mode (group/manual)
    • LED and Button mapping
    5.6 Getting Started

    Summarize steps in 3 phases:

    1. Wiring
    2. Configuration
    3. Integration

    6. Modbus RTU Communication

    Include:

    • Address range and map
    • Input/holding register layout
    • Coil/discrete inputs
    • Register use examples
    • Polling recommendations

    7. ESPHome Integration Guide

    Only if supported. Cover:

    • YAML setup (uart, modbus, package)
    • Entity list (inputs, relays, buttons, LEDs)
    • Acknowledge, override controls
    • Home Assistant integration tips

    8. Programming & Customization

    8.1 Supported Languages
    • MicroPython
    • C / C++
    • Arduino IDE
    • PlatformIO

    The STR-3221-R1 firmware is compatible with standard RP2350 toolchains and examples.
    It uses Modbus RTU libraries, Web Serial (for configuration), and I²C for LED drivers (TLC59208F).


    8.2 Flashing via USB-C

    Firmware updates and development are performed over the USB-C service port.
    The module enumerates as a USB Serial device when connected to a PC.

    Steps:

    1. Connect the module to your PC via USB-C.
    2. Hold Buttons 1 + 2 → the module enters BOOT mode.
      (USB re-enumerates as a flashing device.)
    3. Use the Arduino IDE, PlatformIO, or the provided update utility to upload firmware.
    4. When flashing completes, press Buttons 3 + 4 → triggers hardware RESET and runs the new firmware.
    5. The module reboots and appears as a standard Modbus slave or WebConfig device.

    📷 Button Combination Reference

    Function Combination Behavior
    BOOT Mode Buttons 1 + 2 Forces the module into flash/bootloader mode
    Hardware Reset Buttons 3 + 4 Restarts the MCU without clearing configuration
    Normal Operation Module runs stored firmware automatically

    8.3 Arduino / PlatformIO Notes
    🧩 Required Libraries

    For Arduino or PlatformIO environments, include:

    #include <Arduino.h>
    #include <ModbusSerial.h>
    #include <SimpleWebSerial.h>
    #include <Arduino_JSON.h>
    #include <LittleFS.h>
    #include <Wire.h>
    #include <utility>
    #include "hardware/watchdog.h"
    
    ⚙️ Board Configuration
    Parameter Setting
    Board Generic RP2350
    Flash Size 2 MB (Sketch 1 MB / FS 1 MB)
    Upload Port USB-C
    Baud Rate 115200
    Libraries Modbus RTU, SimpleWebSerial, JSON, LittleFS, Wire
    📡 Pin Mapping Summary
    Peripheral MCU Pin Description
    RS-485 TX GPIO8 MAX485 DI
    RS-485 RX GPIO9 MAX485 RO
    RS-485 DE/RE GPIO10 MAX485 Driver Enable
    Button 1–4 GPIO2, GPIO3, GPIO4, GPIO5 Local input buttons
    LED 1–4 I²C via TLC59208F Status indicators
    I²C SCL / SDA GPIO22 / GPIO23 TLC59208F LED drivers
    Digital Inputs (DI1/DI2) GPIO14 / GPIO15 From ISO1212 isolator outputs
    QSPI Flash GPIO55–60 W25Q32 32 Mbit flash memory
    USB D± GPIO51 / GPIO52 USB-C data lines

    8.4 Firmware Updates
    🧠 How to Update
    1. Connect via USB-C to a PC.
    2. Press Buttons 1 + 2 to enter BOOT mode.
    3. Upload new firmware (e.g., default_str_3221_r1.bin) using:
      • Arduino IDE → “Upload”
      • PlatformIOUpload and Monitor
    4. After flashing, press Buttons 3 + 4 for a safe hardware reset.
    🔒 Preserving Configuration

    All configuration parameters (address, baud, LED/button mappings, etc.) are stored in the MCU’s non-volatile flash and remain intact unless manually erased via WebConfig or serial command.

    🩹 Recovery Methods

    If flashing fails or the module is unresponsive:

    • Disconnect USB-C, wait 10 seconds, and reconnect while holding Buttons 1 + 2 (force BOOT mode).
    • Reflash firmware again.
    • If configuration corruption occurs, select “Factory Reset” in WebConfig.

    9. Maintenance & Troubleshooting

    Indicator / Action Meaning / Resolution
    PWR LED – steady ON Module powered and running normally.
    TX/RX LEDs – blink Active Modbus communication on RS-485.
    No TX/RX blink Check A/B polarity, COM reference, and termination resistors.
    Buttons unresponsive Verify 3.3 V logic; reboot using Buttons 3 + 4.
    No communication via USB-C Ensure Chromium-based browser; close other serial apps.
    Outputs not responding Check 24 V LED PS supply and output VCC rail.
    Digital inputs not changing Verify sensor wiring polarity (INx GND/+); ensure 24 V signal present.
    WebConfig not connecting Use Chrome/Edge; allow serial access permission; reset module if busy.
    Reset Device Press Buttons 3 + 4 for a hardware reboot.
    Full Factory Reset Hold all Buttons 1–4 on power-up to clear configuration.

    10. Open Source & Licensing

    Component License
    Hardware Design (schematics, PCB) CERN-OHL-W v2.0
    Firmware and Example Code GNU GPL v3
    WebConfig / Browser Tools MIT License
    Documentation & Images CC BY-SA 4.0

    All source materials are open for study and modification. Derivative works must retain the same or equivalent license conditions.


    11. Downloads

    Resource Description
    🧠 Firmware (Arduino/PlatformIO) Firmware/default_str_3221_r1/ — main sketch for Modbus, lighting, and WebConfig.
    🛠 WebConfig Tool Firmware/ConfigToolPage.html — browser-based USB-C setup utility.
    📷 Images & Diagrams Images/ — module photos, terminal maps, and block diagrams.
    📐 Schematics (PDF) Schematics/ — FieldBoard and MCUBoard schematics for hardware developers.
    📄 Datasheet & Manual Manuals/ — module datasheet and installation guide.
    📦 Pre-built Firmware Releases page — compiled .bin files for direct flashing.

    12. Support

    If you need help using or configuring the STR-3221-R1, visit:


    HOMEMASTER – Modular control. Custom logic.